- 5 -
CATC/2WSI Installation and Connection Guide - 5 -
Interface Setup
The 2WSI has the communication protocol built into the unit. Depending on which dipswitch selections are made
within the interface will determine which device type it is controlling and which interface number this particular unit is.
In this way you can have several interfaces “talking to” multiple devices on the same system.
1. Remove two screws holding cover on.
2. Remove cover.
Setting Device Type
Using a small screwdriver set the first four dip switches according to the following:
Note: You must have firmware version 1.1.0.0 or higher to control all devices listed on the below chart.
If you do not have this firmware please call Audioaccess Technical Support for the upgrade instructions.
Please contact Technical Support if you need help determining your version. All units shipped after
November 1, 2006 have the version 1.1.0.15.
Device #
DIP 1 DIP 2 DIP 3 DIP 4
Self Test 0
Down
Down
Down
Down
Audio Request – All single zone models 1
Down
Down
Down
Up
Escient Fireball 2
Down
Down
Up Down
n/a 3
Down
Down
Up Up
Russound ST2 AM/FM & XM / SIRIUS 4
Down
Up Down
Down
Lutron Home Works 5
Down
Up Down
Up
Audioaccess aDock+ for iPod® 6
Down
Up Up Down
Russound ST2 DUAL XM or SIRIUS 7
Down
Up Up Up
Audio ReQuest F.Series 2 and 4 Zone and Z.Series
8
Up Down
Down
Down
Setting Interface Address
The next four dip switches are used to set the interface address. This is also used in the CATC Easy Touch II
programming. In order for the interface to work properly the device address must be set on both the hardware and
the software. If you have more than one of each type of device, you will need to set each corresponding interface to a
unique address.
Interface Address
DIP 5
DIP 6
DIP 7
DIP 8
1 Down
Down
Down
Up
2 Down
Down
Up Down
3 Down
Down
Up Up
4 Down
Up Down
Down
5 Down
Up Down
Up
6 Down
Up Up Down
7 Down
Up Up Up
8 Up Down
Down
Down
9 Up Down
Down
Up
10 Up Down
Up Down
Commentaires sur ces manuels